Jaguar Firmware Notes

Ramping Function

  • Ramping works well in Voltage mode, EXCEPT:
    • When moving from high percentages ( >6% or <-6%) to small percentages (between -6% and 6%), ramping no longer will work.
  • In VComp mode, ramping does not seem to work at all, no matter how high the ramping parameters are set.