Jaguar Firmware Notes: Difference between revisions

From 1511Wookiee
Jump to navigationJump to search
(New page: == Jaguar Firmware Notes == === Ramping Function === *Ramping works well in Voltage mode, EXCEPT: ** When moving from high percentages ( >6% or <-6%) to small percentages (between -6% ...)
 
mNo edit summary
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
== Jaguar Firmware Notes ==
== Ramping Function  ==
 
=== Ramping Function  ===


*Ramping works well in Voltage mode, EXCEPT:  
*Ramping works well in Voltage mode, EXCEPT:  
** When moving from high percentages ( >6% or <-6%) to small percentages (between -6% and 6%), ramping no longer will work.
**When moving from high percentages ( &gt;6% or &lt;-6%) to small percentages (between -6% and 6%), ramping no longer will work.  
*In VComp mode, ramping does not seem to work at all, no matter how high the ramping parameters are set.
*In VComp mode, ramping does not seem to work at all, no matter how high the ramping parameters are set.

Latest revision as of 12:58, 16 January 2011

Ramping Function

  • Ramping works well in Voltage mode, EXCEPT:
    • When moving from high percentages ( >6% or <-6%) to small percentages (between -6% and 6%), ramping no longer will work.
  • In VComp mode, ramping does not seem to work at all, no matter how high the ramping parameters are set.