Jaguar Firmware Notes

From 1511Wookiee
Revision as of 11:55, 16 January 2011 by ElectricalMain (talk | contribs) (New page: == Jaguar Firmware Notes == === Ramping Function === *Ramping works well in Voltage mode, EXCEPT: ** When moving from high percentages ( >6% or <-6%) to small percentages (between -6% ...)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search

Jaguar Firmware Notes

Ramping Function

  • Ramping works well in Voltage mode, EXCEPT:
    • When moving from high percentages ( >6% or <-6%) to small percentages (between -6% and 6%), ramping no longer will work.
  • In VComp mode, ramping does not seem to work at all, no matter how high the ramping parameters are set.