Tasks Accomplished

  • Mock electrical board completed to ~90% (radio still needs to be added and wired).
  • Determined that we will be using CAN interface for motor control.
  • Mock Electrical Board finished in Inventor aside from wires.


Tasks to Complete

  • Is 930 packets/sec of CAN traffic alright for programming (using the RS-232 port) motor set points?
  • Research beam sensors for ball sensors (the Q10 was what was used last year).
  • Mount mock board on drivetrain


Important info.

<R47> All active Power Distribution Board branch circuits shall be wired with appropriately sized wire:
A. 12 AWG (2.052mm) or larger diameter wire must be used for all circuits protected by a 40A circuit breaker.
B. 14 AWG (1.628mm) or larger diameter wire must be used for all circuits protected by a 30A circuit breaker.
C. 18 AWG (1.024mm) or larger diameter wire must be used for all circuits protected by a 20A circuit breaker.
D. 20 AWG (0.8128mm) or larger diameter wire must be used for the power connection between the Power Distribution Board and the cRIO-FRC .
E. 20 AWG (0.8128mm) or larger diameter wire must be used for the power connection between the Power Distribution Board and the Linksys Wireless Bridge
F. 20 AWG (0.8128mm) or larger diameter wire must be used for the power connections between the Power Distribution Board and the Analog Breakouts and/or Solenoid Breakout if individual power feeds are used. 18 AWG or larger diameter wire must be used if a common power feed is used for multiple breakouts.
G. 24 AWG (0.5106mm) or larger diameter wire must be used for providing power to pneumatic valves.