2018:Robot IO Map

From 1511Wookiee
Revision as of 16:43, 8 February 2018 by Programming (talk | contribs)
Jump to navigationJump to search

Robot I/O

CAN ID Assignments

ID Subsystem

Component

Type

Model # Description
(brief)
Operation

Notes

(8) max. 40A         PDB #

0 Electrical

PD Module

  Power Distribution Module feedback monitor PD

must be CAN 0

 
1 RESERVED n/a   Factory-default
allows for adding new device quickly and re-assign its ID
  don't use  
2 cube intake RS 775 Talon SRX left Intake cube to hand (+) eject cube (-) 30 A 6
3 cube intake RS 775 Talon SRX right Intake cube to hand (+) eject cube (-) 30 A 7
4 arm RS 775 Talon SRX moves arm   moves from arm front (+) to back (-) 30 A 5
5 hand RS 775 Talon SRX        hold and eject the cube rollers intake (+) eject the cube (-) 30 A 4
6 Left Ramp, Near Jack RS 775 Talon SRX Raise/Lower jack Raise jack (+) 30 A 8
7 Left Ramp, Far Jack RS 775 Talon SRX Raise/Lower jack

Raise jack (+)

Vex encoder feeds direct to talon

40 A 12
8 Right Ramp, Near Jack RS 775 Talon SRX Raise/Lower jack

Raise jack (+)

Vex encoder feeds direct to talon

40 A 3
9 Right Ramp, Far Jack RS 775 Talon SRX Raise/Lower jack

Raise jack (+)

Vex encoder feeds direct to talon

30 A 11
10              
11              
12              
13              
14              
15              
 

PWM Outputs

ID Subsystem

Component

Type

Model # Description
(brief)

Operation

 

Notes

(8) max. 40A              PDB #   

0 DriveBase CIM   SPARK Left Motor 1;  +Voltage = Forwards 40A 0
0 DriveBase CIM   SPARK Left Motor 2; +Voltage = Forwards 40A 1
1 DriveBase CIM   SPARK Right Motor 1; +Voltage = Forwards 40A 15
1 DriveBase CIM   SPARK Right Motor 2; +Voltage = Forwards 40A 14
2              
3              
4              
5              
6              
7              
8              
9              

Relay Outputs

ID Subsystem

Component

Type

Model # Description
(brief)
Operation
Notes
0


1


2


3


Analog IO

RoboRIO Analog Inputs

ID Subsystem

Component

Type

Model # Description
(brief)
Operation

Voltage

Range

Notes
0              
1 Drive gyro TBD gyro telling angle and rate in auto

 

 
2 Arm pot
3852A-282-103AL-ND
arm position arm forward (+) arm back (-) 0-4 v ?  
3              

Rev Robotics More Board Analog IO

ID Subsystem

Component

Type

Model # Description
(brief)
Operation

Voltage

Range

Notes
AIN0              
AIN1              
AIN2              
AIN3              
AOUT0              
AOUT1              
 
 

Digital IO (GPIO)

RoboRio IO

ID Direction
(IN/OUT)
Subsystem

Component

Type

Model # Description
(brief)
Operation Notes
0 IN Drive encoder 63r256 left encoder phase A measures distance traveled 256 counts per rev
1 IN Arm  ???  ??? Limit at end of travel for front of robot Limit "switch" - digital low at limit   
2 IN Drive encoder 63r256 right encoder phase A measures distance traveled 256 counts per rev
3 IN Arm  ???  ??? Limit at end of travel for back of robot Limit "switch" - digital low at limit  
4 IN Intake magnetic reed switch   Intake is all the way out  when it is all the way out it is digital low  
5 IN Arm  encoder srx magnetic encoder arm encoder phase A   1024 counts per rev
6 IN Arm encoder srx magnetic encoder arm encoder phase B   1024 counts per rev
7 IN            
8 IN            
9 IN Hand Allen Bradley diffuse sensor 42EF-D1MNAK-A2 cube present when cube is present digital low needs 10+ volt via PD board #3
 

Rev Robotics More Board IO

ID Direction (IN/OUT) Subsystem Component Type Model # Description (brief) Operation Notes
0              
1              
2              
3              
4              
5              
6              
7              
8              
9              
10              
11              
12              
13              
14              
15              

I2C Registers

Address
(e.g. 0100111X)
Pin
(e.g. GP0)
Subsystem

Component

Type

Model # Description
(brief)
Operation
Notes
0


1


2


3


4


5


6


SPI Devices

#
Subsystem

Component Type

Model # Description (brief) Operation
Notes




 

USB Host Ports

Address
Subsystem

Component Type

Model # Description (brief) Operation
Notes
0
1

Pneumatics Control Module

# Subsystem

Solenoid is Double or Single?

Solenoid

Model #

Description

(brief)

Operation Circuit Pressure Notes
0 Intake Double SY3240-6 Raise intake Extends cylinder to raise intake 60 PSI  
1 Lower intake Retracts cylinder to lower intake  
2 Arm Double SY3240-6 Disengage brake on arm pivot. Does not actually pass air (block output) Extends cylinder to disengage brake 60 PSI  
3 Engage brake on arm pivot Retracts cylinder to engage brake  
4 Arm Double SY3240-6

Release hand's grip on cube

Does not actually pass air (block output)

Removes air pressure from cylinder to "relax" grip on cube  ?? PSI  
5 Tighten hand grip on cube Retracts cylinder to "close" hand  
6 Ramp Double SY3240-6 Holds ramps in stored position Extends cylinder to hold ramps in up position 60 PSI  
7 Allows ramps to deploy to ground Retracts cylinder to release ramps to ground  

Operator Controls

Controller 1 - Primary Driver

 Button/Axis # Action/Button Description Details
A-1 Left Joystick Y Drive Forward/Back

Up drive the robot forward (Intake side)
Down drives the robot backward

NOTE: will do the opposite if swap drive is toggled

  Left Joystick X Nothing  
  Right Joystick Y Nothing  
A-4 Right Joystick X Turn Left/Right

Right will turn the robot clockwise and vice
versa. With no input from the left Joytick,
does point turn. With input from left, does
curve turn

NOTE: will do the opposite if swap drive is toggled

B-5 Left Bumper Slow decreases the range of power to the
motors by a set amount
B-6 Right Bumper Nothing  
A-2 Left Trigger Turbo Increases the range of power to the motors by a set amount.
A-3 Right Trigger Swap Drive

Switches the front and back of the robot.

Press to toggle.

 
 
 
 
 

Controller 2 - Aux Driver

Button/Axis # Action/Button Description Details
A-5 Right Joystick Y Fine Arm Control

Up - towards front

Down - towards back

Only moves arm and intake, when not in moving to a preset.

Moves at a slower speed than the presets.

When broken switches 1 is flipped, the arm will not stop at the front of the robot automatically. The driver is responsible for stopping the arm by letting go of the joystick.

When broken switches 2 is flipped, the arm will not stop at the back of the robot automatically. The driver is responsible for stopping the arm by letting go of the joystick.

B-5 Left Bumper Raise Right Ramp

Press and Hold

If button is let go, then the ramp will stop in place.

If broken switch 5 is flipped, the ramp will not auto-stop when at top. Driver is responsible for stopping.

B-6 Right Bumper Raise Left Ramp

Press and Hold

If button is let go, then the ramp will stop in place.

If broken switch 4 is flipped, the ramp will not auto-stop when at top. Driver is responsible for stopping.

A-3 Right Trigger Intake

Press and Hold

Will auto-stop when cube is all the way in.

If broken switch 6 is flipped, the intake will not auto-stop when cube is fully in.

A-2 Left Trigger Outtake Press and Hold
POV-0 Dpad Up Moves Intake Up

When broken switch 1 is flipped, this moves the intake up.

POV-180 Dpad Down Moves Intake Down When broken switch 1 is flipped, this moves the intake down
B-4 Y button Arm to Intake Level Front  (Preset position)

Press, and release, to move arm and intake there automatically. Doesn't accept any other arm movement requests until the current movement is complete.

When broken switch 1 is flipped, the presets do not work.

B-1 A button Arm to  Exchange Level Back (Preset position)

Press, and release, to move arm and intake there automatically. Doesn't accept any other arm movement requests until the current movement is complete.

When broken switch 1 is flipped, the presets do not work.

B-2 B button Arm to Switch Back (Preset position)

Press, and release, to move arm and intake there automatically. Doesn't accept any other arm movement requests until the current movement is complete.

When broken switch 1 is flipped, the presets do not work.

B-3 X button Arm to Switch Front (Preset position)

Press, and release, to move arm and intake there automatically. Doesn't accept any other arm movement requests until the current movement is complete.

When broken switch 1 is flipped, the presets do not work.

B-7 + B-8 Start + Select Deploy Ramps

Press, and release, both at same time to lower ramps.

Lowers all parts of the ramp. 

 
 

Broken Switches

Switch Description Details
Broken Switch1 Arm/Intake Movement

None of the presets work.

Intake doesn't move in and out with the arm automatically

Broken Switch2 Arm Front Limit Switch Arm won't auto-stop when going towards the front.
Broken Switch3 Arm Back Limit Switch Arm won't auto-stop when going towards the back.
Broken Switch4 Ramp Left Lift Left Ramp doesnt auto-stop when at top.
Broken Switch5 Ramp Right Lift Right Ramp doesn't auto-stop when at top.
Broken Switch6 Cube Intake Cube intake doesn't auto-stop when cube is fully in.